The output resistance of a pressure sensor with voltage output is 5 kΩ. What voltage measurement error does an instrument with 1000 kΩ input resistance cause, if in the given measurement the unloaded output voltage of the sensor were 4.5 V?

Rk5 kΩRb1000 kΩV+−U₀4.5 V
View solution
U_measured = U₀ · Rb / (Rk + Rb)4.478 V
Absolute error ΔU = U₀ − U_measured22.39 mV
Relative error ΔU / U₀0.498 %
View relevant slide (solution method)