🇭🇺Magyar
🎲 Random problem

In a voltage divider circuit supplied by an ideal 12 V voltage generator, resistors R1 = 330 kΩ and R2 = 560 kΩ are used. What measurement error is caused if the voltage of R1 is measured with a voltmeter of input resistance Rb = 2 MΩ? What error does the same voltmeter cause when measuring the supply voltage?

R1330 kΩRb2 MΩVR2560 kΩ+−U₀12 V
View solution
U_before = U₀ · R1 / (R1 + R2)4.449 V
Rₑ = R1 ∥ Rb283.3 kΩ
U_after = U₀ · Rₑ / (Rₑ + R2)4.031 V
Error ΔU (relative)418.5 mV (9.41 %)
Measuring the supply voltage0 V – the internal resistance of the ideal generator is 0 Ω, the voltmeter cannot load it
View relevant slide (solution method)
New problem Back to topic