In a voltage divider circuit supplied by an ideal 12 V voltage generator, resistors R1 = 330 kΩ and R2 = 560 kΩ are used. What measurement error is caused if the voltage of R1 is measured with a voltmeter of input resistance Rb = 2 MΩ? What error does the same voltmeter cause when measuring the supply voltage?
| U_before = U₀ · R1 / (R1 + R2) | 4.449 V |
| Rₑ = R1 ∥ Rb | 283.3 kΩ |
| U_after = U₀ · Rₑ / (Rₑ + R2) | 4.031 V |
| Error ΔU (relative) | 418.5 mV (9.41 %) |
| Measuring the supply voltage | 0 V – the internal resistance of the ideal generator is 0 Ω, the voltmeter cannot load it |